Journal Increasing System Reliability Through Repairing the S phase Hotspot Clamp in Circuit Breaker in the Reactor Bay of the Nagan Raya Substation
Keywords:
Substation, Maintenance, Thermovisi, Hot Spot, Temperature StandardAbstract
Electrical installation equipment is always exposed to factors that cause its condition to deteriorate, such as physical/mechanical, chemical and environmental contact. The factor used as a reference for inspection is the temperature of the operational equipment. Unnatural temperatures will be produced by electrical equipment because electricity is energy that produces heat and worsens the condition of the equipment, so infrared cameras play a role in monitoring the condition of electrical equipment using the temperature of the equipment as a reference. The Thermovision method is a remote monitoring of the temperature conditions of substation equipment when under load to determine the hot temperature of the clamps and conductors and the difference between the two. This journal discusses the repair of hot spots found in the reactor bay Circuit Breaker equipment at the Nagan Raya Main Substation with a temperature of 85.3°C. Temperature standards in determining equipment condition are in accordance with SPLN SK DIR/No.520/2014. Thus, the results of measurements using conductor thermovision in the reactor bay can be used as a reference for preparing further maintenance recommendations.
References
PLN, (2014).Buku Pedomaan Pemeliharaan, No. 0520-2.K/DIR. PT PLN (PERSERO).
Wiwin A. Oktaviani, Taufik Barlian dan M. Agus Salim (2021) Uji Akurasi Dan Uji Presisi Pengukuran Suhu Penghantar Dengan Metode Thermovisi. Teknik Elektro, Universitas Muhammadiyah Palembang.
Jalaluddin Muhammad Akbar1 , Supriyatna, S.T., M.T.2 , Sultan, ST., M.T. ANALISIS HOTSPOT PADA KONDUKTOR DAN MATERIAL TRANSMISI UTAMA MENGGUNAKAN METODE THERMOVISI DI GARDU INDUK TALIWANG. Jurusan Teknik Elektro Universitas Mataram.
Muhamad Ridwan, Teguh Arfianto. Optimalisasi Thermovisi Dalam Menentukan Hot Point
pada Peralatan Bay Penghantar Cikasungka 1 di Gardu Induk 150 kV Rancaekek. Institut Teknologi Nasional Bandung.
Muliadi Sirait, Adi Sastra Tarigan, Siti Anisah. Analysis Of Kutacane Substance Earning System. Faculty of Science and Technology, Electrical Engineering Study Program, Panca Budi Development University, Medan, North Sumatra, Indonesia.
Ika Ayu Wandira, Solly Aryza, Amani Darma Tarigan. A Reliability Analysis Of Supercapacitor Energy Storage In Multi Engine Unlimited Bus Systems Using The Critical Paths Method. Universitas Pembangunan Panca Budi, Medan, North Sumatera, Indonesia.
M. Ridho, Parlin Siagian, Zuraidah Tharo. ANALISIS FREKUENSI GANGGUAN TERHADAP KINERJA SISTEM PROTEKSI GARDU INDUK 150 KV SIEMPAT RUBE. Universitas Pembangunan Panca Budi; Jl. Gatot Subroto No. 4, Kec. Medan Sunggal, Medan, Sumatera Utara.
Eky Firdian Fauzi, Siti Anisah, Hamdani. AN ANALYSIS CAUSES OF LINE DISTURBANCE IN ELECTRICITY DISTRIBUTION IN PT. PLN (PERSERO), ULP EAST BINJAI. Program Study Electrical Engineering, Faculty of Science and Technology Universitas Pembangunan Panca Budi Medan.
Arnanda Putra, Solly Aryza, Zuraidah Tharo. An Analysis Of Power Transformer Performance Reliability On The Effect Transient Recovery Voltage. Universitas Pembangunan Panca Budi, Medan, North Sumatera, Indonesia.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Ahmad Irsyad; Siti Anisah, Adisastra Pengalaman Tarigan
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.