Analysis of The Quality of Electrical Power and Its Impact on PT Pamin Medan Factory Operations
Keywords:
Pamin, Transformer, Electric EnergyAbstract
Pacific Medan Industri (PAMIN), which is located in the modern industrial area of Medan which was established in 1998, is one of the companies engaged in the food sector that produces palmoil-based products such as palm oil, shortening, margarine, cooking oil, special fats, PET bottles including metal printing (printing), cans (cans) and jerry cans for packaging. The problem at PT PAMIN is poor power quality caused by the load on the transformer. The solution is to reduce the use of excess loads, so that the transformer can be more optimal and maximum efficiency. The purpose of this study is to determine the quality of electrical power in PAMIN and analyze the problems of electrical power quality that occur in PAMIN. The results of the active power analysis were obtained at 86,768 kVA. The results of the load analysis were obtained as I average = 91.657 A, IR = 1.08, IS = 1.004, IT = 0.906.
References
S. Anisah, D. Putri Wardani, Rahmaniar, and Hamdani, "Over Current Relay (OCR) Analysis on a 60 MVA Power Transformer with MATLAB Simulation at Payageli Substation," Semin. Soc. Sci. Eng. Hum., 2020.
M. Y. Pohan, D. Pinayungan, M. F. Zambak, and ..., "Analysis of the Design of Solar Power Plants in Residential Houses in Pondok 6," … (Seminar Soc. …, 2021.
A. Carmanto, "ANALYSIS OF IMPROVING THE PERFORMANCE OF 20 KV VOLTAGE ELECTRICAL POWER QUALITY IN INDUSTRY BASED ON ETAP 12.6.0 SIMULATION," Epic J. Electr. Power, Instrum. Control, vol. 2, no. 2, 2019, doi: 10.32493/epic.v2i2.2912
F. Surusa, Q. Aini, A. I. Pratiwi, and Y. Mohamad, "Analysis of Non-Technical Shrinkage Due to Disturbance in the kWh Meter of PT. PLN UP3 Gorontalo," Jambura J. Electr. Electron. Eng., vol. 6, no. 1, 2024, doi: 10.37905/jjeee.v6i1.22380.
S. Anisah, Z. Tharo, and S. Suhardi, "ANALYSIS OF LIMIT VOLTAGE IMPROVEMENT IN 20 KV MEDIUM VOLTAGE NETWORK WITH E-TAP SIMULATION (CASE STUDY OF PT PLN (PERSERO) RAYON KUALA," Pros. Semin. Nas. Tek. UISU, vol. 2, no. 1, 2019.
A. M. Prasetia, S. Riyanto, L. Sartika, and S. Suriadi, "DESIGN OF COS φ SENSOR FOR POWER TRIANGLE MONITORING IN 1-PHASE NETWORK," Elektr. Borneo, vol. 9, no. 2, 2023, doi: 10.35334/eb.v9i2.4381.
F. Husnayain, D. S. Himawan, A. R. Utomo, I. M. Ardita, and B. Sudiarto, "Comparative Analysis of the Performance of LED, CFL, and Incandescent Lamps in Office Lighting Systems," Cyclotron, vol. 6, no. 01, 2023.
T. Nugroho and I. Reza, "ANALYSIS OF MEASUREMENT AND CALCULATION OF TOTAL HARMONIC DISTORTION (THD) AT NONLINEAR LOADS," J. Science Technology. Fak. Tech. Univ. Darma Persada, vol. 12, no. 1, 2022, doi:10.70746/jstunsada.v12i1.166.
H. Nazif, "SIMULATION OF THREE-PHASE RECTIFIER WITH MINIMUM TOTAL HARMONIC DISTORTION WITH RAMP CURRENT CONTROL METHOD OF RAMP CURRENT CONTROL COMPARISON CURRENT CONTROL IN THREE-PHASE ELECTRIC POWER SYSTEM," Ekasakti J. Researcher. Service., vol. 1, no. 2, 2021, doi: 10.31933/ejpp.v1i2.252.
S.- Ardhi, J. P. Sugiono, H. Sutikno, and I. B. Sasaka, "Implementation of Fast Fourier Transform in the Development of Tools and Program Assistance for Measuring Total Harmonic Distortion," SMATIKA J., vol. 9, no. 01, 2019, doi: 10.32664/smatika.v9i01.238.
I. A. Akhinov and Devi Handaya, "EMI Filter Design for 3-Phase Inverter Based on SPWM Method," Pros. SANDIX, vol. 6, no. 2, 2022, doi: 10.36040/cent.v6i2.5031.
N. R. Yuliansyah, F. Achmad, and S. I. Haryudo, "Analysis of Power Loss Repair through the Installation of Bank Capacitors Using Newton Rapshon Method Simulation of Etap 12.6.0 Software at CV Praya Karya East Ring of Sidoarjo," J. Tek. ELECTRIC, vol. 11, no. 1, 2021, doi: 10.26740/jte.v11n1.p23-29.
D. A. Basudewa, "Analysis of the Use of Bank Capacitors on Power Factors in the IDB Laboratory UNESA Building," J. Tek. Electric, vol. 09, no. 03, 2020.
M. Mudjiono, I. Ridzki, and P. Surya, "Application of Particle Swarm Optimization in the Installation of Capacitor Bank in Distribution Networks," ELPOSYS J. Sist. Electrical, vol. 8, no. 3, 2021, doi: 10.33795/elposys.v8i3.81.
R. Pasangkunan, S. A. Karim, and H. Hasrul, "THE EFFECT OF THE INSTALLATION OF A BANK CAPACITOR ON THE POWER FACTOR ON THE REEFER PLUG AT PT. PELINDO IV MAKASSAR NEW PORT BRANCH," J. Media Elektr., vol. 19, no. 1, 2021, doi: 10.26858/metric.v19i1.22231.
R. A. Sinaga, H. Eteruddin, and A. Tanjung, "The Effect of Capacitors on the Power Factor of the Three Phasa Induction Motors at PT. Malindo Karya Lestari," J. Tek., vol. 15, no. 2, 2021, doi: 10.31849/technique.v13i1.2360.
D. Almanda and N. Majid, "An Analysis Study on the Causes of Damage to Capacitor Bank Sub Station Welding at PT. Astra Daihatsu Motor," Resist. (Electronic Communications Network. List. kOmputeR), vol. 2, no. 1, 2019, doi: 10.24853/resistor.2.1.7-1
H. Sungkowo, "Analysis of the failure of the installation of capacitor bank of the central system," J. ELTEK, vol. 18, no. 1, 2020, doi: 10.33795/eltek.v18i1.213.
Y. Rifa'i, "Analysis of Cuitative Research Methodology in Data Collection in Scientific Research on the Preparation of Mini Research," Scholar Inov. And Cultured, vol. 1, no. 1, 2023, doi: 10.59996/cendib.v1i1.155.
A. Faiz, "THE USE OF READING CORNERS IN INSTILLING READING INTEREST IN GRADE 3 STUDENTS AT SDN 1 SEMPLO," J. Pendas Lens, vol. 7, no. 1, 2022, doi: 10.33222/jlp.v7i1.1714.
Downloads
Published
Issue
Section
License
Copyright (c) 2025 Arnold Noverson Laia, Rahmaniar; Haris Gunawan

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.