Design and Analysis of Electrical Installation System For Mahakam Agricultural Supermarket In Tebing Tinggi City, Indonesia

Authors

  • Erikson Tarigan Universitas Pembangunan Panca Budi
  • Siti Anisah Universitas Pembangunan Panca Budi
  • Dino Erivianto Universitas Pembangunan Panca Budi

Keywords:

PUIL2011, SNI 6197:2020, Electrical Installation. Supermarket

Abstract

In designing an electrical installation, it is necessary to pay attention to safety, energy efficiency, and ease of maintenance. PUIL 2011 is a standard that is used as a reference in carrying out electrical installations in a building and SNI 6197:2020 which discusses energy conservation in lighting systems. In this study, an analysis of the design of electrical installations in buildings at the Mahakam agricultural supermarket located in Tebing Tinggi City, North Sumatra was conducted. This study was to determine the suitability of the installation with PUIL 2011 and SNI 6197:2020. From the calculations, it can be seen that the display room on the 2nd floor does not meet the standards of SNI 6197:2020 and also on the 3rd floor the hallway and kitchen area also do not meet the standards of SNI 6197:2020, therefore it is necessary to evaluate the design of lighting installations in these areas. The total active power in the building is 20,378 watts with a total current of 38.70 A. while the installed power from PLN is 33,000 VA after being multiplied by cosφ which is 26,400 watts. The safety devices used in this installation are MCB (Miniature Circuit Breaker) and MCCB (Molded Case Circuit Breaker) through the calculation of the safety current rating have met the PUIL 2011 standard, where the MCCB used on the MDP panel is 100 Ampere and the MCB used on the SDP panel is 40 Ampere.

References

Agrimansyah, M. (2020). Electrical Installation Design at the Central Sulawesi Regional Police's Air and Water Police Directorate Command Headquarters Building, Wina Village. Foristek Scientific Journal, Vol. 10 Number 2.

Alip, M., Rauf, R., & Ridal, Y. (2024). Electrical System Design Review of Stikes Alifah Padang. Journal of Civil Engineering (Electro Civil Engineering), Vol 5, No. 2, Pages 12-22.

Anisah, S., Fitri, R., & Rahmaniar. (2021). Analysis of the Use of Environmentally Friendly Technology-Based Lighting Systems in Residential Homes. Seminar of Social Sciences Engineering & Humanities.

Anisah, S., Rahmaniar, & Indayani, P. (2019). Implementation of resistive and inductiveloads for error testing on single-phase kWh meters. JESCE, Vol 3, No 1 , Pages 30-41.

Dwilesmana, A., & Cahyono, BD (nd). Analysis of Electrical Installation Systems in Multi-Story Buildings at PT. Multi Group.

Fauzan, MZ, & rusdiyanto, d. (2022). Evaluation and Redesign of Electrical Installations of the Management Building and Classrooms at SMAN 6 Garut. Journal of Electrical Engineering Studies, Vol. 6, No. 2.

Ginting, E., Fahreza, M., & Dalimunthe, ME (2024). Electrical Analysis at the Kualanamu Central Service Laboratory. Power Electronics: Jurnal Orang Elektro, Vol. 13, No. 1.

Idris, M., Tharo, Z., & Siagian, P. (2025). Analysis of Prepaid kWh Meter Rejuvenation on Electric Power System Reliability. National Journal of Computer Technology, Vol. 5, No. 3.

Olanda, B., & Susilo, D. (2021). Design and Drafting of Simple Household-Scale Electrical Installations. ELECTRA Journal: Electrical Engineering Articles, Vol. 1, No. 2.

Rahmaniar, & Anisah, S. (2021). Improving Understanding of PUIL 2000 and Illumination Calculations at the Deli Serdang Museum. Abdidas Journal, Vol. 2, no. 3, pp. 646-651.

Saifudin, MA (2018). Analysis of Installed Electrical Power Requirements in the West Halmahera Regent's Office Building. PROTEK Journal, vol 05, No. 1.

Saputra, R., Al Amin, M., & Irwansi, R. (2024). Evaluation of Electrical Installations According to PUIL Standards at CV Multi Teknik. URANUS: Scientific Journal of Electrical Engineering, Science and Informatics, Vol 2, No. 3, Pages 239-245.

Suharto. (2016). Analysis of Electrical Energy Savings at Dr. Soedarso Regional General Hospital, Pontianak, Reviewed from Installation Design. Elkha Journal, Vol. 8, No. 1.

Taryana, t., & Kuntadi, C. (2023). Factors Affecting the Reliability of Electrical Installations. JMPIS, Vol. 4, No. 1.

Tharo, Z., Tarigan, AD, & Pulungan, R. (2018). The Effect of Unbalanced Load Usage on Electrical Equipment Lifespan. RELE (Electrical and Energy Engineering), Vol. 1, No. 1.

Yusuf, & Kali, A. (2020). Electrical Installation Design of the Population and Family Planning Control Office (P2KB) Building, Central Sulawesi Province. Jurnal Ilmiah Foristek, Vol. 10, No. 2.

Downloads

Published

2025-06-24

How to Cite

Tarigan, E., Anisah, S., & Erivianto, D. (2025). Design and Analysis of Electrical Installation System For Mahakam Agricultural Supermarket In Tebing Tinggi City, Indonesia. International Conferance Of Digital Sciences And Engineering Technology , 438–449. Retrieved from https://proceeding.pancabudi.ac.id/index.php/ICDSET/article/view/444

Most read articles by the same author(s)

1 2 > >>